Location -> News
News
Selection of chemical liquid magnetic pump
Selection of chemical liquid magnetic pump
Today, a customer asked how to choose a suitable metering pump for a chemical liquid mixture of water (35%) + acetic acid (25%) + hydrogen peroxide (25%) + peracetic acid (15%)
He provided the following specific demand information:
Medium: water (35%) + acetic acid (25%) + hydrogen peroxide (25%) + peracetic acid (15%)
Flow rate: 2-20ml/m at the beginning, up to 50ml/m at room temperature
Outlet pressure is up to 3bar, usually 1-2bar
After analysis by our technicians, the following specific selection recommendation information was given:
Recommended 0.15CC magnetic pump, material 316+PEEK, this material should be confirmed with the customer whether it is resistant to his medium.
It is not recommended to match the motor with a stepper, and it is best to choose a servo motor with pressure. If you must choose a stepper motor, then choose a 0.3CC magnetic pump head.
If you also encounter specific chemical mixed liquid metering pump selection and quotation issues, please consult CIXIFM winny:
Email: sales01@cxflowmeter.com
Email: sales01@cxflowmeter.com
whatsapp: 008618049841995